Edison ECNR10 ECNR10 | Standard Supply

Edison ECNR Series ECNR10 Time Delay Fuse, 10 A, 250 VAC/125 VDC, 200 kA Interrupt, Class: RK5

  • Item ID: ECNR10
  • Min. Order Qty: 1
  • Item ID: ECNR10
  • Brand: Edison
  • loading

These fuses are recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available short circuit current does not exceed 200000 RMS symmetrical amps. These "dual element, time delay" fuses have minimum industry standard time delay of 10 sec at 5 times the fuse rating (8 sec minimum for 250 V, 30 A and less). The time delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. They are the most popular fuses used in the industry and the most economical for most applications, especially motors and transformers. They have moderate current limitation.

Edison Time Delay Fuse, Series: ECNR Series, Indicating/Non-Indicating: Non-Indicating, 250 VAC/125 VDC, 10 A, Class: RK5, 200 kA Interrupt, 8 s Response, Dual, Ferrule Terminal, Holder Mount, Fiberglass Body, 2 in Length, 0.56 in Dia

  • True dual element construction allows sizing of 125% FLA for motor backup protection
  • Superior overload and cycling capabilities
  • Current limiting provides component short circuit protection
  • Provides motor overload, ground fault and short circuit protection
  • Helps protect motors against burnout from overloads
  • Helps protect motors against burnout from single phasing on three-phase systems
  • Simplifies and improves blackout prevention
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
  • The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the amp rating of the fuse for a minimum of ten sec
Amperage Rating      :      10 A
Body Material      :      Fiberglass
Class      :      RK5
Diameter      :      0.56 in
Element Type      :      Dual
Indicating/Non-Indicating      :      Non-Indicating
Interrupt Rating      :      200 kA
Length      :      2 in
Mounting Type      :      Holder
Response Time      :      8 s
Series      :      ECNR Series
Terminal Type      :      Ferrule
Voltage Rating      :      250 VAC/125 VDC
  • Specification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Edison_ECNR10_Specification_Sheet.pdf
  • Specification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Edison_ECNR10_Specification_Sheet.pdf

Edison ECNR10